For
CONTINUOUS STACK MONITORING
With
BUILT IN TWO POINT CALIBRATION
The MAC 155 In Situ Moisture Analyzer is designed
to continuously monitor emission stack gases.
It is designed to meet EPA and local regulatory requirements for stack gas moisture measurements.
The patented solid state design has been proven in hundreds
of industrial process control applications.
The moisture sensor is extremely rugged and requires no
chemicals, compressed air, optics or mirrors.
to water vapor pressure in the presence of other gasses.
The MAC155 Moisture Analyzer is provided with automatic
two point calibration check at user selectable moisture levels. The
on board calibration system can challenge the sensor with a controlled water
vapor sample. An internal tank holds enough water to generate vapor
samples for one year of daily calibration checks.
Measurement Range
- (MAC155-LT)
- 3% to 15% or 6% to 30% water vapor by volume (user selectable)
- (MAC155-HT)
- 3% to 15%, 6% to 30%, 9% to 45%, or 12% to 60% water vapor by volume (user selectable)
Maximum Stack Gas Temperature
- 1200°F (optional to 2400°F)
Ambient Temperature Range
- 30°F to 140°F (-40°F with case heater option)
Altitude Range
- sea level to 6000 feet
Accuracy
- ±1% of full scale
Linearity
- ±1% of full scale
Response Time
- 60 seconds or less to reach 90% of final value
Analog Output
- 0-20mA or 4-20mA. Internal powered
Power Requirements
- 120V 60HZ @ 3A max
Calibration Check Points
- (MAC155-LT)
- 6% and 12% or 12% and 24%
- (MAC155-HT)
- 6% and 12% or 12% and 24% 0r 18% and 36% or 24% and 48%
Calibration Point Accuracy
- 0.5% of full scale
Distilled Water Tank Capacity
- 26 oz. (22 oz. usable)
Water Usage
- 20 oz. per year
View the MAC155 data sheet in pdf form. (requires Adobe Acrobat reader)
download Acrobat reader
For SPECIFICATIONS & ORDERING INFORMATION>
call us at: (419) 621-2322
Or e-mail us at info@macinstruments.com